¡á Á¤Áö °è·® ¶Ç´Â µ¿Àû °è·®¿¡ ÀûÇÕÇÑ ¿ëµµ ¡á ÀϹݰ跮, Æ÷Àå , ¼±º°, Batching µî ¸ðµç °è·®¿¡ 
                                    »ç¿ë°¡´É ¡á ÃÊ´ç 
70ȸÀÇ Ãʰí¼Ó A/D º¯È¯¼Óµµ-ºü¸¥ »ùÇøµ¼Óµµ ¡á ³»ºÎ ºÐÇØ´É 96,000 count , Ç¥½ÃºÐÇØ´É 1/10,000 ¡á ´Ù¾çÇÑ ºñ±³±â´É : ´Ü¼ø ´©Àû , ´Ü¼ø ¹èÃâ, ºñ±³´©Àû,  
                                      ºñ±³ ¹èÃâ, 
¼±º°±â´É »ç¿ëÀÚ°¡ °è·®½Ã½ºÅÛ ±¸¼º½Ã ´Ù¾çÇÏ°Ô   »ç¿ë°¡´É   ¡á 
ÀÚµ¿³«Â÷º¸Á¤±â´É(Automatic Fee Fall Compensation,    AFFC) :º¸´Ù Á¤È®ÇÑ °øÂ÷¿Í  Á¤¹Ðµµ ¸¦ 
º¸Àå ¡á ³»ÀåµÈ ÀÚµ¿ °è·® ÇÁ·Î±×·¥À» 
ÀÌ¿ëÇÏ¿© .. 
                                    1) ´Ü¼ø ÅõÀÔ °è·®¿¡ ÀÇÇÑ 3´Ü Á¦¾î ±â´É: ´ëÅõÀÔ,   
     ÁßÅõÀÔ, ¼ÒÅõÀÔ ...2) Discharge(loss-in-weight)¿¡ ÀÇÇÑ 2´Ü Á¦¾î±â´É:       ´ë¹èÃâ, 
¼Ò¹èÃâ  ...3) 
Customer Program ¸ðµå : »ç¿ëÀÚ°¡ ºñ±³ ±â´É°ú       ÇÔ²² °è·® ÇÁ·Î±×·¥ µî 
                                    °¡´É **I/O Interfacing ³»Àå Ç׸ñ  
                                       1)Control I/O External 
                                    Interface Batch Mode     2)Setpoint 
                                    External Interface Batch Mode     3)Timing-Normal 
                                    Batching     4)Timing-Loss-In-Weight 
                                    µîµî ¡á Watchdog ±â´É : °íÀå Áõ»ó ¹ß»ý½Ã ÀÚµ¿ÀûÀ¸·Î  Àåºñ¸¦ Ãʱâ 
                                       È ¡á Full Digital Calibration ±â´É ¡á RFI, EMI ¿¡ ¿Ïº®ÇÏ°Ô ´ëÀÀ ¡áOption 
                                    : 
                                    BCD Output,RS-232C,4~20mA ,Setpoint   |  
| 
 »ç        ¾ç 
                                      |  
| 
    Load Cell Excitation   | 
 s12VDC±5%  280mA( Remote sensing limiter for overload Can be sconnected to eight 350§Ù/ 
Load Cells )   |  
| 
    Zero adj. range 
                                                  | 
 s0.35 
mV ~ 24 mV(FDC)   |  
| 
    Input Sensitivity 
                                                  | 
 s0.6§Å/D or greater   |  
| 
    Span Adjustment   | 
 sFDC 
method   |  
| 
    Non -Linearity 
                                                  | 
 s±0.01% of full scale  or less   |  
| 
    Zero Temperature 
    coefficient   | 
 sZero 
±(0.2§Å + 0.0008% of dead load ) / ¡É sSpan ±0.0008/¡É  reading  
  |  
| 
    Input Impedance 
                                                  | 
 s10M§Ùminimum   |  
| 
    Input Noise 
                                                  | 
 s± 
0.3§Åp-p or less   |  
| 
    Maximum display 
    Resolution   | 
 s10,000 counts(Max.)   |  
| 
    Overload Tolerance 
                                                  | 
 sMaximum Capacity plus 9 divisions   |  
| 
    A/D internal Resolution   | 
 s96,000 counts(Max.)   |  
| 
    Sampling Speed 
                                                  | 
 sApproximately 70 Times/sec   |  
| 
    Display Update Rate 
                                                  | 
 s17 
times per sec or 4 times /sec   |  
| 
    Zero Tracking 
                                                  | 
 sProgrammable, from 0.5D/1 sec to 4.5D/2 sec   |  
| 
    Power Requirements 
                                                  | 
 s100,117,200,220, or 240V AC +10% ,-15% s(factory preset) 50/60 Hz 
  |  
| 
    Operating Temp Range   | 
 s-5¡É~ 
40¡É( 23¢µ~ 104¢µ)   |  
| 
    Storage Temp Range 
                                                  | 
 s-15¡É~ +85¡É( -5¢µ~ 185¢µ)   |  
| 
    Operating Humidity 
                                                  | 
 sLess 
 than   85%  RH  ( Non- Condensing)   |  
| 
    Weight   | 
 sApproximately  3kg , 6.6 lb   |  
| 
    Dimensions 
                                                  | 
 s192(W)×187(D)×96(H)§® s7.56(W)×7.36 (D)×3.78(H) inches  
  |  
| 
    Panel Cutout dimensions   | 
 s186 
+ 1.0 /-0(W)×92+ 0.8 /-0(H)§® s7.32 + 0.4 / -0(W)×3.62 + 0.3 / -0(H) 
inches
   |    |  
            |